Or call our service hotline at 021-3630 8185
| Parameter name | Parameter value |
|---|---|
| Equipment appearance dimensions | 800*650*17500mm |
| Rhythm | 30s (original unbalance amount ≤ 8mg) |
| Impeller diameter range | Φ10-50mm |
| Speed range | 6000-150000rpm |
| Dynamic balance correction method | Laser correction |
| Balanced display accuracy | 0.1mg |
| unbalance amount reduction rate | URR≥90% |
| Minimum achievable residual unbalance degree | ≤0.5g.mm/kg |
| Drive mode | self-drive (customer-provided power supply) |
| Equipment power supply | 220V/50Hz |
| Balance correction surface | Single-sided |
| unbalance correction position judgment | CCD |
| Gas source | 0.4-0.6Mpa |
| Safety protection | Fully enclosed |
| Dust removal method | Electric pulse dust removal |

High-speed hair dryer motor, high-speed vacuum cleaner motor, sweeping machine motor, suction pump, dental drill, breathing machine motor, cooling fan