Dynamic balancing solutions for the medical industry

Column: ApplicationsPublished: 2026-09-02Views: 36


1.Dental mobile phone high-speed turbine  

The rotational speed of dental mobile phones is 300,000 to 400,000 r/min. Prolonged close contact with patients can cause imbalance, leading to oral discomfort for patients, hand fatigue for doctors, and premature failure of bearings.It is recommended to use G2Grade 5 and documented in accordance with ISO 13485.Fuman Machinery Desktop test machine balancing Machine & Suitable for laboratories and precision scenarios.

2.Medical centrifuge rotor

The rotational speed of medical centrifuges is 3000-30,000 r/min. Residual imbalance generates huge centrifugal force at high speed, which affects the overall vibration of the machine, the service life of the bearings, and even causes the rotor to fly out.It is recommended to use G25. Regular re-inspection and above.

3.Hemodialysis pump motor

The motor of the hemodialysis pump belongs to life support equipment. It is recommended to be G2.Work in a clean environment of grade 5 and record the entire process in accordance with ISO 13485.

4.Medical nebulizer drive motor

The drive motor of the medical nebulizer has a rotational speed of 8000-15000 r/min and is a high-speed, small brushless motor.

5.Surgical instrument motors (bone drill/grinding drill)

The motor speed of surgical instruments such as bone drills and grinding drills is 10,000-30,000 r/min. G2 is recommended.Grade 5, clean environment operation.

6.Inspection equipment motors (PCR/ biochemical analyzers)

PCR biochemical analyzers and other testing equipment are sensitive to vibration. It is recommended to use G1.0-G2.Grade 5, clean environment operation.

7.Medical compressor motor

The rotational speed of the medical compressor motor (for ventilators and anesthesia machines) is 3000-15000 r/min. G2 is recommended.Level 5, long-term reliability verification.

8.CT instrument motor

The rotational speed of the drive motor for the CT instrument tube is 3000-10000 r/min. It is recommended to use G1.0-G2.It has a precision grade of 5 and strictly controls vibration and noise.

9.Dental drill motor

The motor of the dental drill is a high-speed small motor, similar to that of a dental mobile phone. It is recommended to use G2.Grade 5 clean operation.



×